When recovery drops, the plant floor usually splits into two camps: operators blame equipment wear, while engineers blame changes in the ore. In reality, a single root cause is rare; it is usually a combination of equipment performance degradation and drifting process conditions. To fix the problem, you must use data to pinpoint the loss, not make assumptions.
Nov 19th,2026 3 Views


1. Equipment Issues: Often "Running Sick" Rather Than "Broken Down"

Equipment's impact on recovery is usually gradual and the hardest to spot.

  • Degraded flotation performance: Old flotation cells recover coarse particles poorly and discharge froth inefficiently. In one case, a Jameson flotation cell's downcomer scaled and its air pipes clogged, causing abnormal bubbles. After cleaning, recovery jumped by 15%, with the financial return far exceeding maintenance costs.

  • Auxiliary system failures: In a gold mine, low Knelson concentrator recovery was traced to gold accumulation in the ball mill and pump sump, compounded by insufficient continuous operating time.

  • Ball mill undercharging: A gold mine's ball mill had a filling rate of only 32%, well below the recommended 35%–45%, reducing grinding efficiency.

Core takeaway: Just because equipment is running doesn't mean it's operating efficiently.


2. Process Issues: The Fundamental Constraints of Liberation and Particle Size

If equipment is running normally but recovery remains low, the issue is likely process-related, centering on grinding fineness and mineral liberation.

  • Not ground fine enough: Jinduicheng Molybdenum's low rougher recovery was mainly due to coarse grinding and over-grinding by the classifier; a lithium mine in Sichuan also suffered from excessively coarse feed.

  • Fine enough but still unrecoverable: Micro-fine particles are the natural enemy of flotation. In one copper mine, the -20μm fraction accounted for 47.36% of copper losses in the closed-circuit tailings. Switching equipment won't solve this—it requires adjusting reagents or adding regrinding.

    3. Practical Troubleshooting: A 4-Step Diagnostic Approach

    1. Check particle size distribution: Take samples at various points and run sieve analyses. If tailings losses concentrate in the coarse fractions, check grinding and classification; if in the micro-fine fractions, check reagents and hydrodynamic conditions.

    2. Check actual equipment operating conditions: Don't just see if it's running—check if flotation aeration is uniform, froth discharge is smooth, and ball mill filling rate is up to standard.

    3. Check reagent addition consistency: If recovery varies significantly between shifts—more than ore grade fluctuations can explain—suspect inconsistent reagent dosing first.

    4. Run single-factor comparative tests: In the lab, vary grinding fineness, reagent dosage, and flotation time to see which variable recovery is most sensitive to. If lab results are normal but plant results aren't, the issue is equipment/operation; if the lab also fails, the issue is process/ore properties.

      Conclusion

      Equipment and process are not an either-or choice. Grinding and classification determine "can it be liberated," while flotation hydrodynamics determine "can it be recovered once liberated." The diagnostic logic is: first use particle size data to locate the size fraction where losses occur, then determine whether that fraction is unrecoverable due to equipment or because the process never provided recoverable conditions. Only when both are up to standard can recovery be guaranteed.